>90%

rowred

Very high efficiency heat recovery units

WITH HIGH EFFICIENCY HEAT RECOUPERATOR

from 300 to 4.000 m³/h

Air-handling unit designed and manufactured for non-residential applications, which allows to combine the requirement for air change-over with the maximum energy saving. It is equipped with a counter-flow aluminium plates heat recovery unit, complying specifically with the requirements of the EU 1253/2014 norm. These units naturally integrate with traditional heating/cooling systems though, when equipped with the suitable accessories, they may also be used autonomously.
The series, in both horizontal and vertical execution, is divided into six sizes with air volumes from 300 to 4000 m³/h. The casing is made of 25 mm thick double skin panels, with external sheets in RAL 9002 prepainted galvanized steel and internal ones in galvanized metal sheet, internally insulated with thermo-acoustic fire-proof rockwool insulation. The heat recovery unit has extremely high efficiency (> 90%) in counter-flow aluminium plates, with integrated by-pass system for free-cooling operation.
Filters are M5 efficiency class on room air exhaust and F7 on fresh air intake, efficiency calculated according to EN 779:2012. Fans are backward-curved blades type, directly coupled with EC motors.
The units includes an integrated control board with electronic control of all the functions: ventilation and temperature control, monitoring of the status of the filters, week programming, defrost management and anti-freeze device, fire alarm and Modbus interface.

  • Electric heater for PRE or POST heating

    SKE

    External module with water coil (change-over use)

    CCS

    External module with R410A direct expansion coil

    CDX

    Face/top/bottom air damper (only with PLM)

    SKR1

    Side air damper (only with PLM)

    SKR2

    ON/OFF damper actuator

    SSE

    Modulating 3-way valve with actuator

    V33

    Filters differential pressure switch

    PSTD

    Differential pressure transducer

    DPS

    Ductable CO2 probe

    AQS

    Roof cover for base unit (horizontal versions)

    TPR-H

    Roof cover for base unit (vertical versions)

    TPR-V

    Roof cover for CCS module (horizontal versions)

    TPR-CH

    Roof cover for CCS module (vertical versions)

    TPR-CV

    Flexible connection – upper/lower (only with PLM)

    GAT 1

    Flexible connection – side (only with PLM)

    GAT 2

    Round adapter for circular ducts – upper/lower (only with PLM)

    BCC 1

    Round adapter for circular ducts – side (only with PLM)

    BCC 2

    Plenum with multiple connections

    PLM

HRS

 

 

05

10

15

20

30

40

Airflow rate

Nom

m³/h

450

800

1300

1900

2800

3800

m3/s

0,125

0,222

0,361

0,528

0,778

1,056

External static pressure (1)

Nom

Pa

175

110

250

130

140

105

1m sound pressure level

Nom

dB(A)

53

53

54

60

61

60

Overall power input

Nom

W

330

340

920

930

1820

1920

Max

340

340

920

930

2000

2000

Overall input current

Nom

A

2,7

2,9

6,0

6,0

3,2

3,4

Max

2,8

2,9

36,3

22,6

26,9

24,8

Power supply

V-Ph-Hz

230-1-50

400-3+N-50

Fan speed control

0÷10 V

External leakage

max 3,5 @ -400 Pa (EN 13141-7)

Internal leakage

max 5,5 @ +250 Pa (EN 13141-7)

Yearly filter energy consumption

kWh

476

719

1281

2065

2482

3259

Recovery efficiency (2)

%

91,6

91,4

90,7

90,5

90,3

90,4

Recovery capacity (2)

 

kW

4020

7330

11400

17280

25410

34500

Supply temperature (2)

°C

17,5

17,4

17,2

17,2

17,1

17,1

CONFORMITY TO EU 1253/2014

 

Recovery efficiency (3)

%

83,2

80,0

80,5

80,0

82,5

82,3

Efficiency bonus

W/m³/s

486

390

405

390

465

459

Filter correction factor

0

0

0

0

0

0

SFP int limit

W/m³/s

1667

1556

1552

1510

1548

1500

Total internal air pressure drop (3)

Pa

788

826

743

690

855

873

Overall fan static efficiency (4)

 

%

47,3

55,6

48,1

46,0

56,4

58,3

SFP int

W/m³/s

1666

1485

1545

1500

1516

1498

WORKING LIMITS

 

 

 

 

 

 

 

 

Air temperature

°C

-20 ÷ 45

Air relative humidity

%

10 ÷ 95

Working environment

Not explosive, not corrosive, not chlorinated, not saline.

SKE

 

 

 

 

 

 

 

 

Capacity

kW

1,5

2,5

4,0

5,0

7,5

10,5

∆T (5)

 

°C

9,8

9,2

9,5

7,7

7,9

8,1

Air pressure drop (5)

 

Pa

5

6

10

10

11

12

Power supply

V-Ph-Hz

230-1-50

400-3-50

CCS

 

 

 

 

 

 

 

 

Cooling capacity (6)

total

kW

2,46

4,47

6,65

10,62

16,14

20,68

sensibile

1,35

2,41

3,66

5,84

8,72

11,37

Heating capacity (7)

 

kW

3,30

5,86

9,08

14,03

20,83

27,50

Water flow rate (6)

l/h

432

756

1152

1836

2772

3564

Water pressure drop (6)

kPa

12

18

9

13

19

15

Air pressure drop (6)

Pa

51

53

51

50

50

55

Weight

 

kg

28

31

35

42

52

58

BCC

 

 

Nominal connection diameter

 

mm

250

315

315

400

500

500

Connection strip

mm

100

100

100

100

100

100

Nominal air pressure drop

Pa

7

7

16

10

9

16

(1) Fresh air/supply air circuit
(2) At wet conditions : outside air temperature –7°C 80% RH, room air temperature 20°C 55% RH
(3) At dry conditions : outside air temperature 5°C, room air temperature 25°C
(4) Including motor & speed controller efficiency
(5) At nominal airflow rate
(6) Air inlet condition 28,0°C 60% RH; in/out water temperature 7°/12°C
(7) Air inlet condition 13°C; in/out water temperature 45°/40°C

The table lists the sound power values (SWL) in octave bands and totals; it also indicates the values of sound pressure level (SPL) at 1 m, 5 m and 10 m at supply, return and at the outside of the unit. All values refer to the operation of the ducted unit at FULL speed and at the nominal flow rate.

HRS

SWL [dB] octave banda [Hz]

SWL

SPL Supply

SPL Return

SPL Outside

1 m

5 m

10 m

1 m

5 m

10 m

1 m

5 m

10 m

63

125

250

500

1000

2000

4000

8000

dB

dB(A)

dB(A)

dB(A)

dB(A)

dB(A)

dB(A)

dB(A)

dB(A)

dB(A)

dB(A)

05

62

59

65

65

63

63

62

53

72

69

61

47

41

53

39

33

44

30

24

10

61

58

64

64

62

62

61

53

71

68

60

47

41

53

39

33

44

30

24

15

60

59

65

65

63

63

63

55

72

70

61

48

42

54

40

32

45

31

25

20

66

64

74

73

69

68

68

67

79

76

68

54

48

60

46

40

51

37

31

30

69

66

74

76

72

71

67

67

80

77

69

55

49

61

47

41

52

38

32

40

68

69

72

73

69

70

66

65

79

76

68

54

48

60

46

40

51

37

31

HRS Horizontal version

05

10

15

20

30

40

L

mm

1350

1470

1850

1850

2150

2150

W

mm

680

820

1030

1460

1460

1840

H

mm

330

370

455

455

590

590

W1

mm

760

900

1110

1540

1540

1920

X

mm

230

300

390

600

590

780

Y

mm

225

265

350

350

485

485

E

mm

52,5

52,5

52,5

52,5

52,5

52,5

F

mm

46

46

46

46

55

55

G

mm

128

130

158

170

170

170

D1

½” M

D2

mm

¾” M

¾” M

¾” M

¾” M

1″ M

1″ M

L1

mm

350

400

400

400

502

502

L2

mm

340

380

460

460

580

580

Weight

kg

86

106

181

236

297

367

HRS Vertical version

05

10

15

20

30

40

L

mm

1350

1470

1850

1850

2150

2150

W

mm

330

370

455

455

590

590

H

mm

680

820

1030

1460

1460

1840

X

mm

230

300

390

600

590

780

Y

mm

225

265

350

350

485

485

E

mm

52,5

52,5

52,5

52,5

52,5

52,5

F

mm

46

46

46

46

55

55

F

mm

128

130

158

170

170

170

D1

mm

½” M

D2

mm

¾” M

¾” M

¾” M

¾” M

1″ M

1″ M

L1

mm

350

400

40

400

502

502

L2

mm

340

380

460

460

580

580

Weight

kg

86

106

181

236

297

367

HRS

Automatic / manual speed selection

EC fans management

Manual ON/OFF

Management of cold / change-over valve

CCS+V33

Management of hot valve

CCS+V33

0-10v control of direct expansion coil

CDX

Management of heat recouperator defrost

Management of water coil anti-freeze device

ON/OFF control of pre-heating battery

SKE

Modulating control of pre-heating battery

SKE

Management of free-cooling damper

Management of filters differential pressure switch

PSTD

Management of ventilation with CO2 probe

AQS

Management of ventilation with 1 pressure sensor

DPS

Management of ventilation with PIR occupancy detector

Management of motorized dampers

SKR+SSE

Management of Boost by keyboard

Alarms management

Post ventilation

Weekly programming

Remote ON/OFF

Fire alarm digital input

Mode change (heating/cooling) from digital input

Digital input for PIR occupancy

Remote display with built-in sensor

BMS Modbus protocol RS485

Reference diagram

Click here

Contact form

HRS